User manual
ADA-13040MG
ETHERNET to RS485/RS422 Converter
with MODBUS GATEWAY
1
io_ada-13040MG_en_v1.12
ADA-13040MG
Copyright © 2001-2014 CEL-MAR sp.j.
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - User manual

User manualADA-13040MGETHERNET to RS485/RS422 Converterwith MODBUS GATEWAY1io_ada-13040MG_en_v1.12ADA-13040MGCopyright © 2001-2014 CEL-MAR sp.j.

Page 2

3.3. RS485/RS422 BUS CONNECTIONThe RS485/RS422 interface is available in the ADA-13040MG on screw terminal block, labelled as: Tx+/A, Tx-/B, Rx+, Rx-.

Page 3

Fig. 11. Example connection of the RS485(2W) devices to ADA-13040MG3.3.4. LINE TERMINATION Rt of RS485 BUSThe application of Line Termination (termina

Page 4

5.2. INITIAL CONFIGURATION USING ADAFINDER SOFTWARE5.2.1. ADAFINDER INSTALLATIONThe initial configuration of network setting at the converter can be m

Page 5

Fig. 13. ADAFinder configuration of IP network address5.3. CONFIGURATION AND MANAGEMENT BY THE USE OF INTERNET BROWSERIntegrated WWW server to ADA-130

Page 6

5.3.1. NETWORK CONFIGURATIONTo make a changes of default setting or new configuration of ADA-13040MG, select on left panel Configuration -> Network

Page 7

Fig. 16. Selection serial port profile web5.3.2.1.1. REALPORT (VIRTUAL PORT ) CONFIGURATIONChoosing RealPort (Virtual Port, Fig. 16) is configured the

Page 8

Fig. 17. Example configuration of TCP serverFor configuration of TCP Client Settings (Fig 18), select Automatically establish TCP connections, connect

Page 9

5.3.2.1.2.3. SERIAL PORT TRANSMISSION PARAMETERS CONFIGURATIONFor proper operation of ADA-13040MG with device connected to his RS485/RS422 serial por

Page 10 - ADA-13040MG

5.3.2.1.3.2. UDP CLIENT & SERVER CONFIGURATION IN CASE OF SLAVE DEVICESet operating parameters of UDP server for SLAVE device connected via seria

Page 11

5.3.2.1.3.3. SERIAL PORT TRANSMISSION PARAMETERSFor proper operation of ADA-13040MG with device connected to his RS485/RS422 serial port, should be se

Page 12

Contents1. GENERAL INFORMATION...

Page 13

Fig. 22. Example configuration for communication with MODBUS-MASTER devices – choice of devices and protocolsSet the options in section Modbus RTU

Page 14

Fig. 25. Example configuration for communication with MODBUS-MASTER devices – table entry configuration for SLAVE type devicesOn section Advanced Prot

Page 15

Fig. 27. Example configuration for communication with MODBUS-SLAVE devices – choice of devices and protocolsSet options in section [Modbus RTU Settin

Page 16

ATTENTION !Default port of Industrial Automation (Modbus Gateway) service is 502.If on the local network is conflict with other network service using

Page 17

C/ User Permissions - user permissions to configuration and management of the ADA-13040MG converter, where are an options:None - no permission,Read -

Page 18

6. USING VIRTUAL PORT SERVICE [REALPORT] 6.1. VIRTUAL PORT DRIVER INSTALLATION IN WINDOWS XPThe installation of virtual serial port drivers should be

Page 19

Fig. 31. Devices view on Windows XPFig. 32. Example configuration of multi-port serial adapter 26ADA-13040MG

Page 20

7. FACTORY DEFAULTParameter ValueUser name rootPassword dbpsIP address Obtain an IP address automatically using DHCPOperating mode RealPortBout rate[b

Page 21

Transmission line4-pair twisted cable, UTP 4x2x0,5 (24AWG), shield inside large interferences STP 4x2x0,5 (24AWG)).1-2-pair twisted cable, eg. UTP 1x2

Page 22

6. USING VIRTUAL PORT SERVICE [REALPORT] ...

Page 23

1. GENERAL INFORMATIONThank you for your purchase of CEL-MAR Company product. This product has been completely tested and is covered by two year warra

Page 24

• Power supply 10 - 30 VDC stable min. 3W,• ~ 3000V= optoizolation in signal channel between ETHERNET and RS485/RS422 interface,• 1000V= or 3000V= gal

Page 25

2.3.3. COMMUNICATIONS IN THE SERIAL BRIDGE MODECommunication in the serial bridge mode allows to transfer data via Ethernet network between serial por

Page 26

In the modular socket ETHERNET interface of converter, are implemented two LED's (Fig. 2):– Green ACT signaling state of sending or receiving dat

Page 27

Fig. 5. The WAN connection to operating in the Real Port mode3.2.3. CONNECTION FOR OPERATING IN TCP & UDP SERIAL BRIDGE MODEFig. 6, 7 below show h

Page 28

Fig. 7. The LAN connection to operating in the UDP serial bridge mode, one-to-many3.2.4. CONVERTERS CONNECTION AS MODBUS GATEWAYFigure 8 shows connect

Commentaires sur ces manuels

Pas de commentaire